Title: Выбор оптимальной конфигурации каналов вывода газа в детекторе газового хроматографа
Other Titles: Setting of the optimal output channels configuration in the gas chromatograph detector
Authors: Угланов, Д.А.
Платонов, В.И.
Достовалова, С.С.
Issue Date: 2016
Publisher: Самарский университет
Citation: Материалы докладов междунар. науч.-техн. конф. 22-24 июня 2016 г. Ч. 2, с. 225-227
Abstract: The purpose of the research is to set the optimal output channels configuration in the gas chromatograph detector that provides uniform temperature field distribution at constant gas-flow rate. Have been purposed two options of output channels configuration. Temperature fields in gas chromatograph detector has been calculated by ANSYS software package for mi1tures with various concentrations of air and hydrogen.
Description: УДК 543.544.7.08
URI: http://repo.ssau.ru/jspui/handle/123456789/14419
ISBN: 978-5-7883-1084-8
Appears in Collections:Проблемы и перспективы развития двигателестроения