Отрывок: Any horizontal line on these plots would correspond to a fixed threshold c, and the first intersection of such a line with a plot would correspond to a stopping point for a particular object. It is worth noting that the general behavior for all of the algorithm /object pairs is common and may be described as a monotonous decay. The behavior of the integral algorithms (FBP, HFBP, DFR) is similar between themselves even quantitatively, although the algebraic alg...
Название : Towards monitored tomographic reconstruction: algorithm-dependence and convergence
Авторы/Редакторы : Bulatov, K.B.
Ingacheva, A.S.
Gilmanov, M.I.
Kutukova, K.
Soldatova, Z.V.
Buzmakov, A.V.
Chukalina, M.V.
Zschech, E.
Arlazarov, V.V.
Ключевые слова : anytime algorithms
monitored tomographic reconstruction
micro X-ray computed tomography
nano X-ray computed tomography
dose reduction
time reducing
stopping rule
Дата публикации : Авг-2023
Издательство : Самарский национальный исследовательский университет
Библиографическое описание : Bulatov KB, Ingacheva AS, Gilmanov MI, Kutukova K, Soldatova ZV, Buzmakov AV, Chukalina MV, Zschech E, Arlazarov VV. Towards monitored tomographic reconstruction: algorithm-dependence and convergence to an independent ground truth. Computer Optics 2023; 47(4): 658-667. DOI: 10.18287/2412-6179-CO-1238.
Серия/номер : 47;4
Аннотация : The monitored tomographic reconstruction (MTR) with optimized photon flux technique is a pioneering method for X-ray computed tomography (XCT) that reduces the time for data acquisition and the radiation dose. The capturing of the projections in the MTR technique is guided by a scanning protocol built on similar experiments to reach the predetermined quality of the reconstruction. This method allows achieving a similar average reconstruction quality as in ordinary tomography while using lower mean numbers of projections. In this paper, we, for the first time, systematically study the MTR technique under several conditions: reconstruction algorithm (FBP, SIRT, SIRT-TV, and others), type of tomography setup (micro-XCT and nano-XCT), and objects with different morphology. It was shown that a mean dose reduction for reconstruction with a given quality only slightlyvaries with choice of reconstruction algorithm, and reach up to 12.5 % in case of micro-XCT and 8.5 % for nano-XCT. The obtained results allow to conclude that the monitored tomographic reconstruction approach can be universally combined with an algorithm of choice to perform a controlled trade-off between radiation dose and image quality. Validation of the protocol on independent common ground truth demonstrated a good convergence of all reconstruction algorithms within the MTR protocol.
URI (Унифицированный идентификатор ресурса) : https://dx.doi.org/10.18287/2412-6179-CO-1238
http://repo.ssau.ru/handle/Zhurnal-Komputernaya-optika/Towards-monitored-tomographic-reconstruction-algorithmdependence-and-convergence-107774
Другие идентификаторы : Dspace\SGAU\20231228\107774