Отрывок: An essential factor in this model is the gas flow area (Ag), calculated by multiplying the total cross-sectional area by porosity. Although the mass flow rate fluctuates during calculations, our primary focus lies in the mass-specific cross-sectional area or inverse mass flux (Ag/mc). The coefficient of performance (COP) depends on the ratio of Ag/mc. The cross-sectional area is held constant while adjusting mc to manipulate this ratio. Notably, we assume no heat loss through th...
Название : Analytical modeling and performance analysis of a pulse tube cryocooler
Авторы/Редакторы : Kedam Naresh
Uglanov D. A.
Blagin E. V.
Panshin R. A.
Дата публикации : 2023
Библиографическое описание : Analytical modeling and performance analysis of a pulse tube cryocooler / Kedam Naresh, D. A. Uglanov, E. V. Blagin, R. A. Panshin // Перспективы развития двигателестроения : материалы междунар. науч.-техн. конф. им. Н. Д. Кузнецова (21–23 июня 2023 г.) : в 2 т. / Самар. нац. исслед. ун-т им. С. П. Королева (Самар. ун-т) ; ред. кол. : Е. В. Шахматов, А. И. Ермаков. - Самара : Изд-во Самар. ун-та, 2023. - Т. 2. - С. 326-327.