Отрывок: An essential factor in this model is the gas flow area (Ag), calculated by multiplying the total cross-sectional area by porosity. Although the mass flow rate fluctuates during calculations, our primary focus lies in the mass-specific cross-sectional area or inverse mass flux (Ag/mc). The coefficient of performance (COP) depends on the ratio of Ag/mc. The cross-sectional area is held constant while adjusting mc to manipulate this ratio. Notably, we assume no heat loss through th...
Полная запись метаданных
Поле DC Значение Язык
dc.contributor.authorKedam Nareshru
dc.contributor.authorUglanov D. A.ru
dc.contributor.authorBlagin E. V.ru
dc.contributor.authorPanshin R. A.ru
dc.coverage.spatialanalytical modelingru
dc.coverage.spatialpulse tube cryocoolerru
dc.coverage.spatialregeneratorru
dc.coverage.spatialperformance analysisru
dc.coverage.spatialанализ эффективностиru
dc.coverage.spatialаналитическое моделированиеru
dc.coverage.spatialимпульсные трубчатые криоохладителиru
dc.coverage.spatialрегенераторыru
dc.creatorKedam Naresh, Uglanov D. A., Blagin E. V., Panshin R. A.ru
dc.date.issued2023ru
dc.identifierRU\НТБ СГАУ\540287ru
dc.identifier.citationAnalytical modeling and performance analysis of a pulse tube cryocooler / Kedam Naresh, D. A. Uglanov, E. V. Blagin, R. A. Panshin // Перспективы развития двигателестроения : материалы междунар. науч.-техн. конф. им. Н. Д. Кузнецова (21–23 июня 2023 г.) : в 2 т. / Самар. нац. исслед. ун-т им. С. П. Королева (Самар. ун-т) ; ред. кол. : Е. В. Шахматов, А. И. Ермаков. - Самара : Изд-во Самар. ун-та, 2023. - Т. 2. - С. 326-327.ru
dc.language.isoengru
dc.relation.ispartofПерспективы развития двигателестроения : материалы междунар. науч.-техн. конф. им. Н. Д. Кузнецова (21–23 июня 2023 г.) : в 2 т. - Текст : электронныru
dc.sourceПерспективы развития двигателестроения. - Т. 2ru
dc.titleAnalytical modeling and performance analysis of a pulse tube cryocoolerru
dc.typeTextru
dc.citation.epage327ru
dc.citation.spage326ru
dc.citation.volume2ru
dc.textpartAn essential factor in this model is the gas flow area (Ag), calculated by multiplying the total cross-sectional area by porosity. Although the mass flow rate fluctuates during calculations, our primary focus lies in the mass-specific cross-sectional area or inverse mass flux (Ag/mc). The coefficient of performance (COP) depends on the ratio of Ag/mc. The cross-sectional area is held constant while adjusting mc to manipulate this ratio. Notably, we assume no heat loss through th...-