Отрывок: 0 up to 1.5 mm. The measured depth of the hole was 0.2 mm. 6 Bad lubrication In the normal oiling metal chips in proportion (30 % chips) were added. Comments to Table 2. Each acoustic recording at the same experimental conditions for normal and defect FBs was repeated 15 times. The total number of data points for each recording includes 44100 data points. Each experiment for the given FB was repeated 15 times, the total number of the data point...
Полная запись метаданных
Поле DC Значение Язык
dc.contributor.authorNigmatullin, R.R.-
dc.contributor.authorVorobev, A.S.-
dc.date.accessioned2019-05-08 12:03:10-
dc.date.available2019-05-08 12:03:10-
dc.date.issued2019-05-
dc.identifierDspace\SGAU\20190502\76307ru
dc.identifier.citationNigmatullin R.R. How to read the trendless sequences: the "universal" set of quantitative parameters / Nigmatullin R.R., Vorobev A.S. // Сборник трудов ИТНТ-2019 [Текст]: V междунар. конф. и молодеж. шк. "Информ. технологии и нанотехнологии": 21-24 мая: в 4 т. / Самар. нац.-исслед. ун-т им. С. П. Королева (Самар. ун-т), Ин-т систем. обраб. изобр. РАН-фил. ФНИЦ "Кристаллография и фотоника" РАН; [под ред. В.А. Соболева]. – Самара: Новая техника, 2019. – Т. 3: Математическое моделирование физико-технических процессов и систем. - 2019. - С. 473-482.ru
dc.identifier.urihttp://repo.ssau.ru/handle/Informacionnye-tehnologii-i-nanotehnologii/How-to-read-the-trendless-sequences-the-universal-set-of-quantitative-parameters-76307-
dc.description.abstractWe want to demonstrate a set of “universal” parameters that help to read quantitatively any trendless sequence (TLS). This set will be very useful in order to select the “pattern” noise from the tested one and thereby to solve the problem of calibration of random fluctuations and express some qualitative inputs in terms of these “universal” parameters. This set of quantitative parameters allows to compare the TLS(s) of different nature (acoustic, mechanical, electrochemical, vibrational and etc.) with each other. Using the algorithm, we analysed the acoustic noise recorded from the frictionless bearings (FB) in a normal state and noise from the FBs with artificially created defects. The proposed algorithm allows detecting the desired defect that initially had a qualitative description only. We do suppose that the proposed “universal” scheme free from uncontrollable errors can find a wide application in solution of many practical problems.ru
dc.language.isoenru
dc.publisherНовая техникаru
dc.titleHow to read the trendless sequences: the "universal" set of quantitative parametersru
dc.typeArticleru
dc.textpart0 up to 1.5 mm. The measured depth of the hole was 0.2 mm. 6 Bad lubrication In the normal oiling metal chips in proportion (30 % chips) were added. Comments to Table 2. Each acoustic recording at the same experimental conditions for normal and defect FBs was repeated 15 times. The total number of data points for each recording includes 44100 data points. Each experiment for the given FB was repeated 15 times, the total number of the data point...-
Располагается в коллекциях: Информационные технологии и нанотехнологии

Файлы этого ресурса:
Файл Описание Размер Формат  
paper75.pdfОсновная статья868.09 kBAdobe PDFПросмотреть/Открыть