Отрывок: In particular, the highest macro-weighted recall of 92.2 % is achieved by the CNN model trained on dataset resampled using SMOTE Tomek-Links. While BLSTM and LSTM have better performance when trained on da- taset resampled using SMOTE ENN, CNN and Random Forest models show better performance after SMOTE Tomek-Links resampling. Tab. 1. Comparison of the testing metrics (accuracy, ROC AUC, macro-averaged f1-score, prec...
Полная запись метаданных
Поле DC Значение Язык
dc.contributor.authorShchetinin, E.Y.-
dc.contributor.authorGlushkova, A.G.-
dc.date.accessioned2023-12-29 13:00:12-
dc.date.available2023-12-29 13:00:12-
dc.date.issued2022-12-
dc.identifierDspace\SGAU\20231227\107755ru
dc.identifier.citationShchetinin EY, Glushkova AG. Arrhythmia detection using resampling and deep learning methods on unbalanced data. Computer Optics 2022; 46(6): 980-987. DOI: 10.18287/2412-6179-CO-1112.ru
dc.identifier.urihttps://dx.doi.org/ 10.18287/2412-6179-CO-1112-
dc.identifier.urihttp://repo.ssau.ru/handle/Zhurnal-Komputernaya-optika/Arrhythmia-detection-using-resampling-and-deep-learning-methods-on-unbalanced-data-107755-
dc.description.abstractDue to cardiovascular diseases millions of people die around the world. One way to detect abnormality in the heart condition is with the help of electrocardiogram signal (ECG) analysis. This paper's goal is to use machine learning and deep learning methods such as Support Vector Machines (SVM), Random Forests, Light Gradient Boosting Machine (LightGBM), Convolutional Neural Network (CNN), Long Short-Term Memory (LSTM) and Bidirectional Long Short-Term Memory (BLSTM) to classify arrhythmias, where particular interest represent the rare cases of disease. In order to deal with the problem of imbalance in the dataset we used resampling methods such as SMOTE Tomek-Links and SMOTE ENN to improve the representation ration of the minority classes. Although the machine learning models did not improve a lot when trained on the resampled dataset, the deep learning models showed more impressive results. In particular, LSTM model fitted on dataset resampled using SMOTE ENN method provides the most optimal precision-recall trade-off for the minority classes Supraventricular beat and Fusion of ventricular and normal beat, with recall of 83 % and 88 % and precision of 74 % and 66 % for the two classes re-spectively, whereas the macro-weighted recall is 92 % and precision is 82 % .ru
dc.description.sponsorshipThe authors would like to acknowledge the use of the University of Oxford Advanced Research Computing (ARC) facility in carrying out this work: http://dx.doi.org/10.5281/zenodo.22558. Specifications: https://www.arc.ox.ac.uk/arc-systems.ru
dc.language.isoenru
dc.publisherСамарский национальный исследовательский университетru
dc.relation.ispartofseries46;6-
dc.subjectmachine learningru
dc.subjectdeep learningru
dc.subjectECGru
dc.subjectresamplingru
dc.subjectarrhythmiaru
dc.titleArrhythmia detection using resampling and deep learning methods on unbalanced dataru
dc.typeArticleru
dc.textpartIn particular, the highest macro-weighted recall of 92.2 % is achieved by the CNN model trained on dataset resampled using SMOTE Tomek-Links. While BLSTM and LSTM have better performance when trained on da- taset resampled using SMOTE ENN, CNN and Random Forest models show better performance after SMOTE Tomek-Links resampling. Tab. 1. Comparison of the testing metrics (accuracy, ROC AUC, macro-averaged f1-score, prec...-
dc.classindex.scsti28.17.37-
Располагается в коллекциях: Журнал "Компьютерная оптика"