Отрывок: 3. Computer simulation We have designed the miniature prism-based stereoscopic system and performed the computer simulation of calibration using Zemax optical design software. The designed system has the following characteristics: f/11, field of view 40°×45° in each channel, range of working distances 5-40 mm and 1/6” image sensor with 1920×1080 pixels. We simulated the cali...
Полная запись метаданных
Поле DC Значение Язык
dc.contributor.authorGorevoy, A.V.-
dc.contributor.authorMachikhin, A.S.-
dc.contributor.authorBatshev, V.I.-
dc.contributor.authorKoluchkin, V.Ya.-
dc.date.accessioned2019-04-22 10:53:16-
dc.date.available2019-04-22 10:53:16-
dc.date.issued2019-
dc.identifierDspace\SGAU\20190418\75265ru
dc.identifier.citationGorevoy A.V. Calibration simulation for stereoscopic optical systems using optical design software / A.V. Gorevoy, A.S. Machikhin, V.I. Batshev, V.Ya. Koluchkin // Сборник трудов ИТНТ-2019 [Текст] : V междунар. конф. и молодеж. шк. "Информ. технологии и нанотехнологии" : 21-24 мая : в 4 т. / Самар. нац.-исслед. ун-т им. С. П. Королева (Самар. ун-т), Ин-т систем. обраб. изобр. РАН-фил. ФНИЦ "Кристаллография и фотоника" РАН ; [под ред. Р. В. Скиданова]. - Самара: Новая техника, 2019. - Т. 1 : Компьютерная оптика и нанофотоника. - 2019. - С. 153-157.ru
dc.identifier.urihttp://repo.ssau.ru/handle/Informacionnye-tehnologii-i-nanotehnologii/simulation-for-stereoscopic-optical-systems-using-optical-design-software-75265-
dc.description.abstractTo reconstruct three-dimensional (3D) structure of objects and measure their geometric parameters using stereoscopic imaging systems, it is necessary to implement a number of image processing algorithms. For higher system efficiency, the choice of these algorithms and mathematical models should be taken into account at the stage of optical system design. We demonstrate the capabilities of optical design software to perform computer simulation of geometrical calibration for stereoscopic systems. The simulation allows comparison of mathematical models used for 3D reconstruction and estimation of 3D measurements errors caused by tolerances of optical elements, temperature variations and other factors. Using this technique, we analyze the design of prism-based stereoscopic system and show that the proposed ray tracing camera model considering pupil aberrations provides higher measurement precision. The results of computer simulation are confirmed by experiments with the self-developed stereoscopic system.ru
dc.language.isoenru
dc.publisherИзд-во «Новая техника»ru
dc.titleCalibration simulation for stereoscopic optical systems using optical design softwareru
dc.typeArticleru
dc.textpart3. Computer simulation We have designed the miniature prism-based stereoscopic system and performed the computer simulation of calibration using Zemax optical design software. The designed system has the following characteristics: f/11, field of view 40°×45° in each channel, range of working distances 5-40 mm and 1/6” image sensor with 1920×1080 pixels. We simulated the cali...-