Отрывок: The number of unknowns in the equations for finding the minimum flow was reduced to 𝑂(𝑁) from 𝑂(𝑁2) in matrices consisting of 𝑁 points. Empirically, it was shown that the new algorithm has 𝑂(𝑁2) time, while the classical algorithm shows 𝑂(log𝑛𝑁3) complexity. In this work, it was shown that the algorithm constructed for 𝐿1 could be adapted to find 𝐿1𝛼 without increasing the level of ...
Полная запись метаданных
Поле DC Значение Язык
dc.contributor.authorGuryanova V.ru
dc.coverage.spatialwaveletsru
dc.coverage.spatialAugmentationru
dc.coverage.spatialdeep learningru
dc.coverage.spatialECG signalru
dc.coverage.spatialEMDru
dc.coverage.spatialвейвлетыru
dc.coverage.spatialаугментация данныхru
dc.coverage.spatialглубокое обучениеru
dc.coverage.spatialмобильные ЭКГru
dc.coverage.spatialЭКГru
dc.creatorGuryanova V.ru
dc.date.issued2022ru
dc.identifierRU\НТБ СГАУ\495994ru
dc.identifier.citationGuryanova, V. Scalogram-EMD distance for mobile ECGs / V. Guryanova // Информационные технологии и нанотехнологии (ИТНТ-2022) : сб. тр. по материалам VIII Междунар. конф. и молодеж. шк. (г. Самара, 23 - 27 мая) : в 5 т. / М-во науки и образования Рос. Федерации, Самар. нац. исслед. ун-т им. С. П. Королева (Самар. ун-т), Ин-т систем обраб. изобр. РАН - фил. ФНИЦ "Кристаллография и фотоника" РАН. - Самара : Изд-во Самар. ун-та, 2022Т. 5: Науки о данных / под ред. А. В. Куприянова. - 2022. - С. 053352.ru
dc.description.abstractNow there are devices that are capable of recording ECGs. The distance between signals can be helpful in classification problems for finding ECGs like the given one to know the expected disease scenario. This paper proposes a new distance based on the wavelet decomposition of the signal and earth mover's distance with a new base distance function. It is shown that the introduced distance is a metric over theconsidered signal equivalence classes. In addition, a method for creating new signals based on the developed distance has beenproposed, which can be used to augment data when training deep neural networks. Finally, an experimental study has demonstrated that the generated signals can improve classification qualityru
dc.language.isoengru
dc.relation.ispartofИнформационные технологии и нанотехнологии (ИТНТ-2022) : сб. тр. по материалам VIII Междунар. конф. и молодеж. шк. (г. Самара, 23 - 27 мая) : в 5 т. -ru
dc.sourceИнформационные технологии и нанотехнологии (ИТНТ-2022). - Т. 5 : Науки о данныхru
dc.titleScalogram-EMD distance for mobile ECGsru
dc.typeTextru
dc.citation.spage053352ru
dc.citation.volume5ru
dc.textpartThe number of unknowns in the equations for finding the minimum flow was reduced to 𝑂(𝑁) from 𝑂(𝑁2) in matrices consisting of 𝑁 points. Empirically, it was shown that the new algorithm has 𝑂(𝑁2) time, while the classical algorithm shows 𝑂(log𝑛𝑁3) complexity. In this work, it was shown that the algorithm constructed for 𝐿1 could be adapted to find 𝐿1𝛼 without increasing the level of ...-